Skip to content
Skip to content
Perspective

Choosing Ultrasonic Cleaner Frequency: 28/40 kHz, Dual and Triple

28 kHz suits heavy oil and robust metal parts, 40 kHz is the general-purpose band, and 80–120 kHz suits precision parts and fine particles. For mixed soils, choose dual or triple frequency.

An ultrasonic cleaner's frequency determines the size of its cavitation bubbles. The lower the frequency, the larger the bubbles and the stronger the impact, which suits heavy oil and structurally robust metal parts. The higher the frequency, the smaller the bubbles and the gentler the action, which suits precision parts, polished surfaces and fine particles. In practice, 28 kHz is used for heavy oil, 40 kHz is the general-purpose band, and 80–120 kHz is used for precision cleaning. If the same batch carries both coarse and fine contamination, consider a dual- or triple-frequency model.

Why does frequency affect cleaning results?

Ultrasonic cleaning works through cavitation: the transducers make the liquid oscillate at high speed, creating large numbers of tiny bubbles, and the local impact when they collapse lifts contamination off the surface. The Wikipedia article "Ultrasonic cleaning" gives common frequencies as "usually from 20 – 40 kHz" and explains that a higher frequency means smaller nodes between cavitation points, so finer details can be reached (source).

LEO's application page explains the same effect in terms of the boundary layer: the surface of a part carries an almost stationary film of liquid where fine particles hide. This acoustic boundary layer becomes thinner as frequency rises, so high frequencies reach fine particles that low frequencies cannot (Particulates and metal fines). Conversely, each low-frequency bubble carries more energy, which helps penetrate thick oil films, but on thin sheet, polished surfaces or precision-turned parts it can erode the surface.

Common frequencies at a glance

The table below summarises typical uses for each frequency band and the LEO models whose product pages currently list that frequency. The use descriptions are taken from LEO's product and industry pages; the actual configuration still has to be assessed against your parts and contaminants.

FrequencyCavitationTypical parts / soilsLEO models listing this frequency
28 kHzLarge bubbles, strong impactHeavy oil and drawing compounds on stamped and machined parts, steel tubes, castings, motor housingsSingle-tank integrated L-10600 series, single-tank separate L-600 series, smart LS series, immersible transducer LT series (28/40 kHz selectable); LEO-6002 series
40 kHzGeneral-purpose bandMost machined and stamped parts, PCBs and FPCs, stainless steel surgical instrument setsThe industrial models above (28/40 kHz selectable); benchtop LEO-2003, LEO-3002S, LEO-400S and others
46 kHzGeneral-purpose band close to 40 kHzGeneral cleaning with benchtop and household unitsBenchtop LEO-100, LEO-150, LEO-801 and others; household LEO-50
80 kHzGentlerOptical lenses, electronic components, precision-turned partsSingle-tank dual-frequency (40/80 kHz combination), single-tank triple-frequency series
120 kHzSmall, dense bubblesPrecision or finished surfaces, implants, sub-micron particlesLEO-6002 series, LEO-3002H, LEO-400H, LEO-1002H and others; single-tank dual-frequency (40/120 kHz combination), single-tank triple-frequency series

The selection page of Japan's Honda Electronics uses a similar classification: 28 kHz for degreasing stubborn soils such as oil and grease; 40 kHz, often used for precision parts, with less damage to parts than 28 kHz; 75–100 kHz where 40 kHz would damage the part; 120–160 kHz for initial wafer cleaning; and 400 kHz up to the MHz range for even finer particles on wafers and glass substrates (source). MHz-range cleaning is a dedicated semiconductor process and falls outside the scope of general industrial cleaners.

Single, dual, triple and sweep frequency compared

TypeHow it worksBest forPoints to note
Single frequencyOne frequency per tankFixed parts and soil types, e.g. a line dedicated to removing stamping oilIf the parts change or the soils get finer, you may need a second machine
Dual frequencySwitch between two frequencies in the same tankA lower frequency for heavy oil first, then a higher frequency for residues and precision surfacesLEO dual-frequency models come in 28/40, 40/80 and 40/120 kHz combinations; choose the combination for your parts first
Triple frequencySwitch between three frequencies in the same tankOne machine that must cover metal parts, delicate parts and high cleanliness requirementsLEO triple-frequency models are 40/80/120 kHz and do not include 28 kHz
Sweep (wideband frequency modulation)Frequency varies continuously across a rangeReducing uneven cleaning caused by single-frequency standing wavesThis is a generator function; confirm whether a given model offers it when you request a quote

Frequency sweep addresses standing waves. LEO's buying guide notes that single-frequency cleaners are affected by a standing-wave field: amplitude is small at the nodes and large at the antinodes, which causes uneven cleaning, and it states that wideband frequency modulation cleans better (How to choose an ultrasonic cleaner). If a machine has no sweep function, you can improve uniformity by oscillating the basket, turning the parts or changing how they are positioned.

Three checks for choosing frequency by part

  • Part strength: robust steel parts, castings and motor housings can take 28 kHz; thin sheet, polished surfaces, precision-turned parts and assembled components should avoid frequencies that are too low.
  • Soil size: heavy stamping oil, drawing compounds and carbon deposits lean towards 28/40 kHz; fine particles, polishing residue and sub-micron particles lean towards 80/120 kHz.
  • Mixed soils: chips inside holes are a mechanical blockage. LEO's application page recommends clearing the larger debris first at 28 or 40 kHz, then treating the fine remainder at high frequency, which is exactly what dual- and triple-frequency tanks are for.

Taking LEO's industry pages as examples, 28/40 kHz is recommended for stamped conductive parts, 40 kHz for PCBs and FPCs, and 80/120 kHz for precision electronic components (Electronics industry); stainless steel instrument sets generally use 40 kHz, while implants and polished surfaces go up to 80 or 120 kHz (Medical and surgical instruments industry).

How should the cleaning solution match the frequency?

Frequency provides the physical action and the cleaning solution provides the chemical action, so choose them together. General guidelines:

  • Water-based alkaline detergents: for oily soils such as machining oil, stamping oil, cutting oil and rust-preventive oil; the most common choice for metal parts.
  • Neutral detergents: for materials sensitive to acids and alkalis, such as glass and optics; the priority is easy rinsing with no residue.
  • Acidic detergents: for rust, scale and oxides; parts usually need a neutralising rinse or rust prevention afterwards.
  • Solvents: for soils that water-based detergents struggle with, or where parts must be completely dry. These systems are mostly vapour degreasers, and solvents should not be poured directly into an ordinary open water-tank cleaner.

LEO's industrial ultrasonic cleaning detergents page lists the pH and use of each product, for example LEO-108 (pH 10, metalworking oil and rust-preventive oil), LEO-112Y (pH 12.8, adhesive residue on precision electronics and PCB flux), LEO-116 (pH 7, precision glass) and LEO-104 (pH 2.5, rust removal from steel). Follow each detergent's own instructions for dilution ratio and temperature.

FAQ

Do I always need to add detergent to an ultrasonic cleaner?

Plain water can remove loose dust and some water-soluble soils, but grease, flux and polishing compound need a detergent to loosen them from the surface first so that cavitation can carry them away. Choose the detergent according to both the part material and the contaminant.

Can I use flammable solvents such as alcohol or gasoline in an ultrasonic cleaner?

Flammable solvents are not recommended in an ordinary water-tank cleaner. The Wikipedia article warns that ultrasonic operation heats the bath, so flammable cleaning liquids should be avoided (source). If you need solvent cleaning, use a system designed for solvents.

What temperature should the cleaning solution be?

LEO's buying guide recommends 40–60 ℃ for water-based solutions; in cold weather a bath that is too cool weakens cavitation. Biological soils such as blood and protein are the opposite: LEO's application page recommends about 35–45 ℃ to keep proteins from setting under heat. In all cases, follow the detergent's recommended temperature.

Can 28 kHz damage precision parts?

It can. 28 kHz produces larger bubbles and stronger impact, and LEO's industry pages advise against using it on thin sheet, polished surfaces and precision-turned parts. Such parts usually go to 40 kHz or higher, or are sent for a sample cleaning test before deciding.

How do I choose between dual and triple frequency?

If your parts have both heavy oil and fine features, a dual-frequency model that includes 28 kHz (28/40 kHz) is the better fit. If the focus is precision parts, optics or fine particles, a 40/80/120 kHz triple-frequency model covers a wider range. The difference comes down to whether you need 28 kHz as the lowest band.

Can an existing cleaning tank be converted to ultrasonic?

Consider immersible ultrasonic transducers. LEO's immersible transducer LT series consists of a transducer pack and an ultrasonic generator, can be built for bottom, side or top mounting depending on the installation position, and runs at 28/40 kHz (Immersible ultrasonic transducer series).

Frequency selection comes back to the part itself: material, geometry, contaminants and cleanliness requirements. Start with the specifications of LEO's single-tank dual-frequency integrated series, single-tank triple-frequency integrated series and LEO-6002 series. For unusual parts, Custom and OEM solutions explains the process of sample cleaning tests and system design, or you can send us your part details via Contact us.

Perspective

Request a Quote

Tell us what you need cleaned

Send us the part, the contaminant and your cycle time. Our engineers size the tank, the frequency and the process chain — and reply with a sized specification for your line.

LINEPhoneRequest a Quote